Type:
Bug
-
Status: Done (View Workflow)
-
Priority:
Major
-
Resolution: Done
-
Affects Version/s: 7.0, 7.1
-
Fix Version/s: None
-
Labels:None
-
Environment:
Multipath (MPIO) iSCSI connection to Compellent storage (Dell Storage Center) using SCOS 7.1.4.4
-
Team:
Wrong commandline for 'scsi_id' built and executed to get LUN SCSI ID.
Please check following threads:
http://discussions.citrix.com/topic/384576-scan-target-fails-on-xenserver-7-and-compellent-sc9000/
http://discussions.citrix.com/topic/384581-xenserver7-and-dell-compellent-issues-sc4020/